Checking the AC/DC supply
When a false alarm occurs which hasn’t been triggered by user error, the first thing that should be checked is the AC/DC power supply. It is critical for the AC/DC supply to be stable to prevent random false alarms and control panel crashes. An AC supply fault or low capacity battery would cause PIRs to trigger falsely and cause LIMs to lockout.
Alarm installers have a duty of care to ensure the AC supply is safe BEFORE connecting the control equipment. Voltage, polarity and Earth loop resistance are the most essential safety tests to perform when checking this power supply. Loop faults can only be performed using a mains multitester such as the ACT Easiplus. Test for stable DC voltage between 13.5 min and 14.0 max at battery, PIRs, keypads and LIMs. Remember, AC/DC problems can only be prevented by testing during installation and service inspections.